💧 Type 1 of 4
Weak Flow
Every nozzle is still working, there is just far less water than there used to be. This is the most common complaint and almost always a restriction upstream of the faceplate: the inlet filter screen, a clogged flow restrictor, or scale across the whole nozzle field.
What usually causes it
- Inlet filter screen blocked with sediment or pipe debris
- Flow restrictor clogged, or a low-flow disc fitted by the previous owner
- Limescale film across the faceplate reducing every orifice at once
- Supply valve partly closed, or a pressure drop elsewhere in the house
Checks, in order
- Run the shower with the head removed. Strong flow at the arm means the problem is in the head; weak flow there means it is in the valve or supply.
- Look into the threaded inlet. Most heads have a conical mesh screen sitting right at the opening.
- Check the rating stamped on the head or restrictor — 1.5 and 1.8 gpm heads feel weak next to an old 2.5 gpm unit.
- Open the shower valve fully and confirm no other fixture is running.
What fixes it
- Rinse the inlet screen under a tap, then pick out embedded grit with a toothpick.
- Soak the head face-down in white vinegar for 4–8 hours, then brush the nozzles.
- If the restrictor is clogged, clean it before considering removal — and check local water-use rules first.
- Replace a cracked or deformed screen; they cost a couple of dollars.
When to stopIf flow at the open arm is still weak with the head off, the cartridge or supply line is the problem. That is valve work, not shower-head work.